Event Type Date Time Source

Failure 21-Jul-2001 17:00:00 Logbook I, Page 7
Run and bypass valve failure. Dislodged manually.

Insert Change 21-Jul-2001 18:26:33 HCLog 36553
Insert ??? Top: ??? (Deut) Bot: ??? (Deut)

Calibration 22-Jul-2001 18:40:00 Logbook I, Page 10
LHe level vs. scattering rate study.

Calibration 22-Jul-2001 23:38:32 HCLog 36635
Target position scan w/ beam.

Calibration 23-Jul-2001 19:15:00 Logbook I, Page 14
LHe level vs. beam position study.

Calibration 24-Jul-2001 04:14:00 Logbook I, Page 18
Target vs. Encoder position. Jon Farrell calculated.

Calibration 23-Jul-2001 23:11:26 Logbook I, Page 19
Encoder position. Josh Pierce calculated.

Calibration 24-Jul-2001 02:02:10 HCLog 36693
Densities for various materials.

Calibration 24-Jul-2001 11:00:00 Logbook I, Page 21
Scattering rates vs. Encoder position.

Change 24-Jul-2001 11:49:00 Logbook I, Page 22
New 3He manometer installed, old one removed.

Calibration 24-Jul-2001 17:00:00 Logbook I, Page 23
Table to be positioned by encoder values.

Change 24-Jul-2001 20:00:00 Logbook I, Page 23
Insert plunger pins changed from plastic to stainless.

Failure 24-Jul-2001 22:30:00 Logbook I, Page 23
Bypass valve problem. Physically reset bypass valve.

Change 24-Jul-2001 23:31:18 HCLog 36747
New encoder positions.

Calibration 25-Jul-2001 15:00:00 Logbook I, Page 28
Insert pin position vs. insert angle plots.

Failure 25-Jul-2001 18:32:00 Logbook I, Page 29
Magnet quench.

Failure 26-Jul-2001 04:37:00 Logbook I, Page 30
Raster off w/ beam on bottom ND3 target.

Failure 26-Jul-2001 22:41:48 HCLog 36888
Magnet quench.

Calibration 26-Jul-2001 23:09:46 HCLog 36889
Encoder and target table values.

Calibration 26-Jul-2001 23:50:32 HCLog 36891
Pictures of beam spot on ammonia.

Change 27-Jul-2001 01:08:00 Logbook I, Page 31
Copper disk inserted in "empty" position. Also hclog 36890.

Calibration 27-Jul-2001 05:00:00 Logbook I, Page 32
Chart for He3 vs. temperature.

Calibration 28-Jul-2001 03:00:00 Logbook I, Page 34
Target position plot using copper insert.

Calibration 29-Jul-2001 00:55:00 Logbook I, Page 36
Encoder values recalculated.

Change 29-Jul-2001 03:45:00 Logbook I, Page 37
Windows based DAQ installed in SOS hut.

Change 29-Jul-2001 04:30:26 HCLog 37009
New encoder values.

Change 29-Jul-2001 18:22:00 Logbook I, Page 38
Cable changes to DIO box and DAQ computer. NMR retuned.

Change 30-Jul-2001 08:00:00 Logbook I, Page 40
Cryostat moved by 4mm to recenter target with beam.

Change 31-Jul-2001 08:44:00 Logbook I, Page 41
Terminators attached to unused SMA connectors on insert.

Change 31-Jul-2001 11:00:00 Logbook I, Page 42
Replaced section of phase cable suspected to be bad.

Change 31-Jul-2001 11:48:00 Logbook I, Page 42
Sampling frequency changed so noise and sweep are out of phase.

TE Calibration 31-Jul-2001 14:04:10 Logbook I, Page 42
Deuteron 20 samples 1.553K

TE Calibration 31-Jul-2001 18:05:07 Logbook I, Page 43
Deuteron 11 samples 1.563K

Calibration 31-Jul-2001 23:00:00 Logbook I, Page 46
Peak asymmetry polarization calculated.

Calibration 01-Aug-2001 11:50:00 Logbook I, Page 47
Gain setting were adjusted on Baselines.

Change 01-Aug-2001 11:50:00 Logbook I, Page 47
RF power cable swapped on Q-meters for noise reasons.

Change 01-Aug-2001 12:57:00 Logbook I, Page 48
Several cables changed on try to eliminate noise on bottom target.

Calibration 01-Aug-2001 13:55:00 Logbook I, Page 48
Switches for target position adjusted.

Failure 02-Aug-2001 01:51:00 Logbook I, Page 53
Pumps tripped off.

Failure 02-Aug-2001 09:10:00 Logbook I, Page 55
Pumps tripped off.

Calibration 02-Aug-2001 16:04:47 HCLog 37254
Materials composing target.

Anneal 02-Aug-2001 20:34:00 Logbook I, Page 56
80K 45 minutes

Anneal 04-Aug-2001 09:59:48 Logbook I, Page 61
80K 45 minutes

Change 04-Aug-2001 12:00:00 Logbook I, Page 61
Qmeters retuned.

TE Calibration 04-Aug-2001 14:31:00 Logbook I, Page 62
Deuteron 15 samples 1.574K

Change 04-Aug-2001 17:00:00 Logbook I, Page 63
Phase cable switched on bottom cell.

TE Calibration 04-Aug-2001 17:33:27 Logbook I, Page 63
Deuteron 16 samples 1.588K

TE Calibration 05-Aug-2001 20:59:00 Logbook I, Page 67
Deuteron 15 samples 1.677K

Failure 06-Aug-2001 09:50:00 Logbook I, Page 70
Separator valve not working. Computer rebooted.

Anneal 06-Aug-2001 11:01:00 Logbook I, Page 70
Empty Target 80K 35 minutes

Change 07-Aug-2001 09:55:00 Logbook I, Page 76
Labview restarted to correct spurious polarization reading.

Anneal 08-Aug-2001 09:45:00 Logbook I, Page 82
Empty Target 60K 45 minutes

Anneal 08-Aug-2001 18:00:00 Logbook I, Page 84
Empty Target 80K 10 minutes

Anneal 09-Aug-2001 18:20:00 Logbook I, Page 92
Empty Target 80K 25 minutes

Anneal 10-Aug-2001 17:28:00 Logbook I, Page 100
Empty Target 90K 45 minutes

Anneal 12-Aug-2001 08:21:00 Logbook I, Page 106
85K 39 minutes

Calibration 13-Aug-2001 04:30:00 Logbook I, Page 110
Polarization decay study.

Failure 14-Aug-2001 09:45:00 Logbook I, Page 112
Safety crew forced restricted access - ramp down magnet.

Insert Change 15-Aug-2001 10:00:00 Logbook I, Page 113
Insert C Top: Gen01_Bottle_3 (Deut) Bot: 95%_Gen01_Bottle_1,5%_Gen01_Bottle_2 (Deut)

TE Calibration 16-Aug-2001 00:16:00 Logbook I, Page 114
Deuteron 21 samples 1.617K

TE Calibration 16-Aug-2001 01:48:00 Logbook I, Page 115
Deuteron 22 samples 1.629K

Failure 16-Aug-2001 05:00:00 Logbook I, Page 116
Pump trip.

Failure 17-Aug-2001 13:15:00 Logbook I, Page 122
Separator valve stuck.

Anneal 18-Aug-2001 12:00:00 Logbook I, Page 127
0K 0 minutes

Calibration 19-Aug-2001 16:30:00 Logbook I, Page 133
Lambda/2 cable lengths: top=184cm, bot=191cm, top phase=76cm, v=0.78

Anneal 19-Aug-2001 16:38:00 Logbook I, Page 133
82K 35 minutes

Failure 19-Aug-2001 18:24:00 Logbook I, Page 133
Pump trip.

TE Calibration 21-Aug-2001 10:48:00 Logbook I, Page 144
Deuteron 19 samples 1.635K

TE Calibration 21-Aug-2001 13:23:00 Logbook I, Page 144
Deuteron 20 samples 1.639K

TE Calibration 21-Aug-2001 15:43:00 Logbook I, Page 144
Deuteron 17 samples 1.638K

TE Calibration 21-Aug-2001 16:35:00 Logbook I, Page 144
Deuteron 20 samples 1.647K

Anneal 21-Aug-2001 18:19:00 Logbook I, Page 147
Empty Target 95K 15 minutes

Anneal 22-Aug-2001 23:59:00 Logbook I, Page 152
Empty Target 95K 30 minutes

Anneal 24-Aug-2001 10:21:00 Logbook I, Page 157
95K 45 minutes

Failure 27-Aug-2001 00:56:00 Logbook II, Page 13
Pump fuse blown while preparing for anneal.

Anneal 27-Aug-2001 01:06:00 Logbook II, Page 13
95K 60 minutes

Anneal 28-Aug-2001 21:30:00 Logbook II, Page 20
95K 60 minutes

Failure 29-Aug-2001 06:25:00 Logbook II, Page 22
Pumps tripped off

Calibration 31-Aug-2001 07:03:00 Logbook II, Page 32
Possible Decay measurement.

Change 31-Aug-2001 07:35:01 Logbook II, Page 32
He3 Manometer removed.

TE Calibration 31-Aug-2001 12:31:02 Logbook II, Page 34
Deuteron 20 samples 1.413K

TE Calibration 31-Aug-2001 16:08:41 Logbook II, Page 35
Deuteron 20 samples 1.418K

TE Calibration 31-Aug-2001 22:21:44 Logbook II, Page 37
Deuteron 20 samples 1.423K

TE Calibration 01-Sep-2001 03:24:00 Logbook II, Page 38
Deuteron 19 samples 1.592K

TE Calibration 01-Sep-2001 06:08:00 Logbook II, Page 39
Deuteron 19 samples 1.639K

TE Calibration 01-Sep-2001 10:09:22 Logbook II, Page 40
Deuteron 20 samples 1.648K

TE Calibration 01-Sep-2001 12:41:55 Logbook II, Page 41
Deuteron 19 samples 1.658K

TE Calibration 01-Sep-2001 14:03:30 Logbook II, Page 41
Deuteron 20 samples 1.653K

TE Calibration 01-Sep-2001 21:56:00 Logbook II, Page 44
Deuteron 10 samples 1.643K

TE Calibration 01-Sep-2001 23:04:00 Logbook II, Page 44
Deuteron 15 samples 1.637K

TE Calibration 02-Sep-2001 00:59:00 Logbook II, Page 45
Deuteron 10 samples 1.641K

TE Calibration 02-Sep-2001 03:15:00 Logbook II, Page 46
Deuteron 13 samples 1.641K

Change 02-Sep-2001 04:28:00 Logbook II, Page 46
Scale on He4 manometer changed to accommodate 1.9 K TE.

TE Calibration 02-Sep-2001 05:08:00 Logbook II, Page 47
Deuteron 12 samples 1.876K

TE Calibration 02-Sep-2001 07:43:51 Logbook II, Page 48
Deuteron 20 samples 1.878K

TE Calibration 02-Sep-2001 09:18:46 Logbook II, Page 49
Deuteron 20 samples 1.881K

TE Calibration 02-Sep-2001 12:04:00 Logbook II, Page 50
Deuteron 16 samples 1.880K

TE Calibration 02-Sep-2001 13:21:00 Logbook II, Page 50
Deuteron 10 samples 1.887K

TE Calibration 02-Sep-2001 14:17:00 Logbook II, Page 51
Deuteron 20 samples 1.895K

Anneal 04-Sep-2001 16:26:00 Logbook II, Page 52
Empty Target 95K 60 minutes

Anneal 07-Sep-2001 15:25:00 Logbook II, Page 67
Empty Target 95K 45 minutes

Anneal 08-Sep-2001 23:40:00 Logbook II, Page 72
Empty Target 95K 60 minutes

Failure 09-Sep-2001 05:24:00 Logbook II, Page 73
Run valve stuck.

Change 09-Sep-2001 19:00:00 HCLog 40359
EPICS data added to the event stream via EDR.vi

Anneal 10-Sep-2001 09:18:00 Logbook II, Page 78
95K 60 minutes

Anneal 11-Sep-2001 11:48:00 Logbook II, Page 83
Empty Target 95K 60 minutes

Failure 13-Sep-2001 17:10:00 Logbook II, Page 88
Target mover problem.

Anneal 13-Sep-2001 17:25:00 Logbook II, Page 89
Empty Target 95K 90 minutes

Failure 14-Sep-2001 08:00:00 Logbook II, Page 90
Target mover problem.

Change 15-Sep-2001 00:03:00 Logbook II, Page 92
One month shut down preparations.

TE Calibration 17-Sep-2001 02:45:11 Logbook II, Page 94
Deuteron 21 samples 1.532K

TE Calibration 17-Sep-2001 05:16:20 Logbook II, Page 95
Deuteron 22 samples 1.537K

TE Calibration 17-Sep-2001 08:12:13 Logbook II, Page 96
Deuteron 10 samples 1.531K

TE Calibration 17-Sep-2001 09:14:22 Logbook II, Page 96
Deuteron 10 samples 1.546K

TE Calibration 17-Sep-2001 10:35:05 Logbook II, Page 97
Deuteron 11 samples 1.549K

TE Calibration 17-Sep-2001 12:03:36 Logbook II, Page 97
Deuteron 10 samples 1.550K

TE Calibration 17-Sep-2001 13:36:24 Logbook II, Page 98
Deuteron 10 samples 1.554K

TE Calibration 17-Sep-2001 16:00:14 Logbook II, Page 98
Deuteron 11 samples 1.560K

TE Calibration 17-Sep-2001 17:27:58 Logbook II, Page 99
Deuteron 10 samples 1.543K

Anneal 17-Sep-2001 18:33:00 Logbook II, Page 99
95K 60 minutes

Calibration 18-Sep-2001 07:52:00 Logbook II, Page 103
Polarization decay study.

Insert Change 18-Sep-2001 14:00:00 Logbook II, Page 104
Insert C Top: xxx (Deut) Bot: xxx (Deut)

Calibration 18-Sep-2001 15:00:00 Logbook II, Page 104
Compared He3 to He4 manometer.

Change 19-Sep-2001 16:00:00 Logbook II, Page 107
Shut down.

Insert Change 14-Oct-2001 15:00:00 Logbook II, Page 109
Insert x Top: xxx (Deut) Bot: xxx (Deut)

Calibration 14-Oct-2001 15:01:00 Logbook II, Page 109
He3 to He4 calibration.

Change 15-Oct-2001 12:00:00 Logbook II, Page 110
He3 and He4 manometers adjusted.

Insert Change 15-Oct-2001 20:00:00 Logbook II, Page 112
Insert B Top: E155_Bottle_4_+_Gen_Bottle_1 (Deut) Bot: 6/7/01_Consol_+_Gen_Bottle_1 (Deut)

TE Calibration 17-Oct-2001 11:12:37 Logbook II, Page 113
Deuteron 20 samples 1.543K

TE Calibration 17-Oct-2001 14:34:12 Logbook II, Page 114
Deuteron 20 samples 1.528K

TE Calibration 22-Oct-2001 16:28:55 Logbook II, Page 114
Deuteron 20 samples 1.528K

Calibration 22-Oct-2001 12:00:00 Logbook II, Page 116
He4 and He3 temperature chart.

Change 22-Oct-2001 15:07:00 Logbook II, Page 117
Wiring chart for MIO card connections.

TE Calibration 22-Oct-2001 18:08:08 Logbook II, Page 118
Deuteron 10 samples 1.584K

TE Calibration 22-Oct-2001 19:34:26 Logbook II, Page 119
Deuteron 10 samples 1.577K

TE Calibration 22-Oct-2001 20:58:22 Logbook II, Page 120
Deuteron 10 samples 1.573K

TE Calibration 22-Oct-2001 22:20:29 Logbook II, Page 120
Deuteron 10 samples 1.668K

TE Calibration 22-Oct-2001 23:45:47 Logbook II, Page 122
Deuteron 5 samples 1.563K

TE Calibration 23-Oct-2001 00:36:11 Logbook II, Page 123
Deuteron 10 samples 1.552K

TE Calibration 23-Oct-2001 02:07:51 Logbook II, Page 124
Deuteron 10 samples 1.555K

TE Calibration 23-Oct-2001 03:34:40 Logbook II, Page 125
Deuteron 10 samples 1.558K

TE Calibration 23-Oct-2001 05:03:11 Logbook II, Page 126
Deuteron 10 samples 1.570K

TE Calibration 23-Oct-2001 06:24:05 Logbook II, Page 127
Deuteron 11 samples 1.575K

TE Calibration 23-Oct-2001 07:47:23 Logbook II, Page 128
Deuteron 11 samples 1.575K

TE Calibration 23-Oct-2001 11:10:49 Logbook II, Page 130
Deuteron 10 samples 1.573K

TE Calibration 23-Oct-2001 12:29:39 Logbook II, Page 131
Deuteron 10 samples 1.578K

TE Calibration 23-Oct-2001 13:56:28 Logbook II, Page 132
Deuteron 13 samples 1.555K

TE Calibration 23-Oct-2001 15:54:55 Logbook II, Page 133
Deuteron 10 samples 1.562K

TE Calibration 23-Oct-2001 17:11:44 Logbook II, Page 134
Deuteron 11 samples 1.566K

TE Calibration 23-Oct-2001 18:38:16 Logbook II, Page 134
Deuteron 10 samples 1.565K

TE Calibration 23-Oct-2001 20:11:25 Logbook II, Page 136
Deuteron 11 samples 1.564K

TE Calibration 23-Oct-2001 21:41:42 Logbook II, Page 137
Deuteron 10 samples 1.561K

TE Calibration 23-Oct-2001 23:07:38 Logbook II, Page 138
Deuteron 8 samples 1.561K

TE Calibration 24-Oct-2001 04:48:48 Logbook II, Page 140
Deuteron 10 samples 1.303K

TE Calibration 24-Oct-2001 06:17:41 Logbook II, Page 141
Deuteron 10 samples 1.287K

TE Calibration 24-Oct-2001 07:39:35 Logbook II, Page 144
Deuteron 11 samples 1.287K

TE Calibration 24-Oct-2001 09:07:36 Logbook II, Page 146
Deuteron 12 samples 1.286K

TE Calibration 24-Oct-2001 14:16:05 Logbook II, Page 147
Deuteron 10 samples 1.630K

Calibration 24-Oct-2001 17:45:00 Logbook II, Page 148
Top target baseline with field off.

Calibration 24-Oct-2001 19:55:00 Logbook II, Page 148
Manometer field sensitivity measurement.

Failure 27-Oct-2001 16:30:00 Logbook II, Page 152
Fuse in microwave switch blown.

Failure 28-Oct-2001 02:19:00 Logbook II, Page 153
Pump trip

Failure 28-Oct-2001 09:30:00 Logbook II, Page 154
Temperature readings failed.

Failure 28-Oct-2001 15:30:00 Logbook II, Page 155
Microwave switch malfunctioning.

Anneal 29-Oct-2001 13:25:00 Logbook II, Page 160
85K 30 minutes

TE Calibration 30-Oct-2001 14:39:46 Logbook II, Page 163
Deuteron 10 samples 1.534K

Failure 31-Oct-2001 19:38:00 Logbook II, Page 166
Microwave switch not working.

Anneal 01-Nov-2001 10:06:00 Logbook II, Page 168
Carbon Target 80K 60 minutes

Change 02-Nov-2001 10:00:00 Logbook II, Page 173
Bottom deuteron taken at gain 50.

Change 02-Nov-2001 10:15:00 Logbook II, Page 173
Microwave switch removed and replaced with strait waveguide.

Anneal 02-Nov-2001 11:35:00 Logbook II, Page 174
80K 10 minutes

Anneal 03-Nov-2001 16:09:00 Logbook II, Page 179
Empty Target 65K 15 minutes

Anneal 05-Nov-2001 01:01:00 Logbook II, Page 185
Empty Target 65K 5 minutes

Anneal 05-Nov-2001 17:11:00 Logbook II, Page 189
Carbon Target 75K 10 minutes

Failure 05-Nov-2001 17:25:00 Logbook II, Page 190
Run valve stuck due to ice.

Change 06-Nov-2001 10:00:00 Logbook II, Page 192
MIO card in computer replaced.

TE Calibration 06-Nov-2001 12:51:47 Logbook II, Page 193
Deuteron 12 samples 1.499K

TE Calibration 06-Nov-2001 14:29:31 Logbook II, Page 194
Deuteron 10 samples 1.474K

Anneal 06-Nov-2001 16:56:00 Logbook II, Page 195
Empty Target 80K 10 minutes

Anneal 07-Nov-2001 10:08:00 Logbook II, Page 200
Empty Target 85K 10 minutes

Anneal 08-Nov-2001 11:01:00 Logbook II, Page 207
Empty Target 95K 15 minutes

Anneal 09-Nov-2001 22:52:00 Logbook II, Page 213
Carbon Target 95K 30 minutes

Failure 10-Nov-2001 02:30:00 Logbook II, Page 214
Run valve stuck.

Anneal 11-Nov-2001 00:37:00 Logbook II, Page 217
Empty Target 95K 45 minutes

Anneal 12-Nov-2001 08:54:00 Logbook II, Page 221
95K 60 minutes

Anneal 13-Nov-2001 17:57:00 Logbook II, Page 226
Carbon Target 95K 60 minutes

Anneal 14-Nov-2001 17:09:00 Logbook II, Page 230
Empty Target 95K 51 minutes

Anneal 15-Nov-2001 19:37:00 Logbook II, Page 235
Empty Target 95K 60 minutes

Anneal 16-Nov-2001 21:08:00 Logbook II, Page 240
Empty Target 95K 60 minutes

Failure 18-Nov-2001 01:25:00 Logbook II, Page 245
Computer crash during anneal.

Anneal 18-Nov-2001 01:30:00 Logbook II, Page 246
95K 30 minutes

Anneal 18-Nov-2001 23:45:00 Logbook II, Page 256
Empty Target 95K 75 minutes

Anneal 19-Nov-2001 23:30:00 Logbook II, Page 260
Empty Target 95K 60 minutes

Failure 20-Nov-2001 17:20:00 Logbook II, Page 264
Separator valve stuck.

Anneal 20-Nov-2001 18:38:00 Logbook II, Page 264
Empty Target 95K 60 minutes

Change 21-Nov-2001 08:00:00 Logbook II, Page 269
Preparations for holiday shutdown made.

TE Calibration 26-Nov-2001 14:12:43 Logbook II, Page 270
Deuteron 10 samples 1.538K

TE Calibration 26-Nov-2001 15:42:02 Logbook II, Page 271
Deuteron 10 samples 1.554K

TE Calibration 26-Nov-2001 17:11:17 Logbook II, Page 272
Deuteron 10 samples 1.536K

TE Calibration 26-Nov-2001 18:51:50 Logbook II, Page 272
Deuteron 10 samples 1.550K

TE Calibration 26-Nov-2001 20:07:05 Logbook II, Page 273
Deuteron 10 samples 1.551K

TE Calibration 26-Nov-2001 21:19:52 Logbook II, Page 274
Deuteron 10 samples 1.547K

TE Calibration 26-Nov-2001 22:38:41 Logbook II, Page 274
Deuteron 10 samples 1.542K

TE Calibration 26-Nov-2001 23:56:35 Logbook II, Page 275
Deuteron 10 samples 1.546K

TE Calibration 27-Nov-2001 01:18:18 Logbook II, Page 275
Deuteron 10 samples 1.551K

TE Calibration 27-Nov-2001 02:44:49 Logbook II, Page 276
Deuteron 10 samples 1.573K

TE Calibration 27-Nov-2001 04:07:19 Logbook II, Page 276
Deuteron 10 samples 1.546K

TE Calibration 27-Nov-2001 05:29:08 Logbook II, Page 277
Deuteron 10 samples 1.554K

TE Calibration 27-Nov-2001 06:52:35 Logbook II, Page 277
Deuteron 10 samples 1.554K

Change 27-Nov-2001 08:10:00 Logbook II, Page 278
Gain 50 used for baselines in following TEs.

TE Calibration 27-Nov-2001 08:25:32 Logbook II, Page 278
Deuteron 10 samples 1.553K

TE Calibration 27-Nov-2001 10:02:11 Logbook II, Page 279
Deuteron 10 samples 1.538K

TE Calibration 27-Nov-2001 11:30:22 Logbook II, Page 279
Deuteron 10 samples 1.548K

Failure 27-Nov-2001 13:35:00 Logbook II, Page 280
Material fell out of cups.

Insert Change 27-Nov-2001 15:00:00 Logbook II, Page 281
Insert C Top: 50%_Gen01_Bottle_1,50%_Gen01_Bottle_2 (Deut) Bot: 66%_Gen01_Bottle_5,14%_Gen01_Bottle_6,20%_Gen01_Bottle_2 (Deut)

TE Calibration 27-Nov-2001 20:19:12 Logbook II, Page 282
Deuteron 10 samples 1.540K

TE Calibration 27-Nov-2001 21:34:37 Logbook II, Page 283
Deuteron 10 samples 1.539K

TE Calibration 27-Nov-2001 22:48:20 Logbook II, Page 283
Deuteron 10 samples 1.543K

TE Calibration 28-Nov-2001 00:50:47 Logbook II, Page 284
Deuteron 10 samples 1.559K

TE Calibration 28-Nov-2001 02:09:16 Logbook II, Page 284
Deuteron 10 samples 1.534K

TE Calibration 28-Nov-2001 03:32:26 Logbook II, Page 285
Deuteron 10 samples 1.539K

TE Calibration 28-Nov-2001 05:38:01 Logbook II, Page 285
Deuteron 10 samples 1.554K

TE Calibration 28-Nov-2001 07:16:24 Logbook II, Page 286
Deuteron 10 samples 1.557K

TE Calibration 28-Nov-2001 08:54:02 Logbook II, Page 286
Deuteron 10 samples 1.517K

TE Calibration 28-Nov-2001 11:34:48 Logbook II, Page 287
Deuteron 10 samples 1.527K

Failure 28-Nov-2001 18:15:00 Logbook II, Page 287
Microwave switch malfunctioning.

Failure 28-Nov-2001 21:30:00 Logbook II, Page 288
Magnet quench.

Calibration 29-Nov-2001 01:23:00 Logbook II, Page 289
Relaxation study.

Calibration 30-Nov-2001 15:00:00 Logbook II, Page 289
Beam found to be uncentered.

Change 01-Dec-2001 00:05:00 Logbook II, Page 289
Encoder values changed.

Anneal 01-Dec-2001 21:29:00 Logbook II, Page 295
95K 60 minutes

Anneal 02-Dec-2001 21:51:00 Logbook II, Page 299
Empty Target 100K 60 minutes

Failure 04-Dec-2001 08:25:00 Logbook III, Page 1
GPIB interface changed out.

TE Calibration 04-Dec-2001 10:55:16 Logbook III, Page 2
Deuteron 9 samples 1.510K

TE Calibration 04-Dec-2001 12:25:13 Logbook III, Page 3
Deuteron 20 samples 1.542K

TE Calibration 04-Dec-2001 13:48:22 Logbook III, Page 3
Deuteron 10 samples 1.511K

TE Calibration 04-Dec-2001 15:25:31 Logbook III, Page 4
Deuteron 10 samples 1.532K

TE Calibration 04-Dec-2001 17:45:49 Logbook III, Page 5
Deuteron 10 samples 1.518K

TE Calibration 04-Dec-2001 19:02:54 Logbook III, Page 5
Deuteron 10 samples 1.522K

Anneal 04-Dec-2001 20:50:00 Logbook III, Page 6
95K 60 minutes

Anneal 08-Dec-2001 01:43:00 Logbook III, Page 15
Empty Target 95K 60 minutes

Failure 08-Dec-2001 03:20:00 Logbook III, Page 15
Run valve stuck.

Failure 08-Dec-2001 17:05:00 Logbook III, Page 17
run valve stuck.

Anneal 09-Dec-2001 05:16:00 Logbook III, Page 19
Carbon Target 100K 60 minutes

Anneal 10-Dec-2001 06:54:00 Logbook III, Page 24
100K 60 minutes

Failure 10-Dec-2001 11:30:00 Logbook III, Page 25
Power tripped to target racks.

Failure 11-Dec-2001 08:02:00 Logbook III, Page 29
Power tripped to target racks.

Calibration 11-Dec-2001 08:15:00 Logbook III, Page 29
Relaxation study.

TE Calibration 11-Dec-2001 15:40:05 Logbook III, Page 30
Deuteron 9 samples 1.531K

TE Calibration 11-Dec-2001 17:00:31 Logbook III, Page 31
Deuteron 11 samples 1.522K

TE Calibration 11-Dec-2001 20:09:14 Logbook III, Page 32
Deuteron 5 samples 1.540K

TE Calibration 11-Dec-2001 21:25:48 Logbook III, Page 32
Deuteron 10 samples 1.554K

TE Calibration 11-Dec-2001 22:49:45 Logbook III, Page 34
Deuteron 10 samples 1.551K

Anneal 12-Dec-2001 01:04:00 Logbook III, Page 56
Empty Target 100K 60 minutes

Anneal 13-Dec-2001 01:50:00 Logbook III, Page 42
Empty Target 100K 60 minutes

Anneal 14-Dec-2001 07:49:00 Logbook III, Page 49
105K 60 minutes

Anneal 15-Dec-2001 10:43:00 Logbook III, Page 55
Top Target 105K 60 minutes

Anneal 16-Dec-2001 01:40:00 Logbook III, Page 57
Empty Target 105K 30 minutes

Failure 16-Dec-2001 06:48:00 Logbook III, Page 57
Run valve stuck.

Anneal 16-Dec-2001 22:34:00 Logbook III, Page 61
105K 60 minutes

Anneal 17-Dec-2001 17:00:00 Logbook III, Page 64
Top Target 105K 60 minutes

Calibration 18-Dec-2001 04:00:00 Logbook III, Page 66
Decay study.

TE Calibration 18-Dec-2001 14:50:33 Logbook III, Page 68
Deuteron 7 samples 1.547K

TE Calibration 18-Dec-2001 16:06:15 Logbook III, Page 69
Deuteron 11 samples 1.569K

TE Calibration 18-Dec-2001 17:27:50 Logbook III, Page 69
Deuteron 10 samples 1.567K

TE Calibration 18-Dec-2001 20:35:19 Logbook III, Page 71
Deuteron 10 samples 1.517K

TE Calibration 18-Dec-2001 22:01:49 Logbook III, Page 72
Deuteron 10 samples 1.552K

Anneal 19-Dec-2001 00:15:00 Logbook III, Page 73
Top Target 110K 60 minutes

Anneal 19-Dec-2001 23:30:00 Logbook III, Page 78
Empty Target 110K 60 minutes

Anneal 20-Dec-2001 17:33:00 Logbook III, Page 82
Empty Target 115K 60 minutes

Calibration 21-Dec-2001 00:46:00 Logbook III, Page 84
Polarization dependence on scan steps and scan frequency.

Change 21-Dec-2001 06:00:00 Logbook III, Page 85
Shutdown.